GeForce RTX 4090 blower: Difference between revisions
Jump to navigation
Jump to search
(새 문서: GeForce RTX 4090 blower models comes from Manli) |
No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
GeForce RTX 4090 blower models comes from Manli | GeForce RTX 4090 blower models comes from Manli and Gallaxy | ||
== 4090 Power consumption == | |||
Although RTX 4090 default max. power cap shows 450W from the output of nvidia-smi command. | |||
[[File:4090 nvidia-smi.png|center|frameless|549x549px]] | |||
The actual power consumption including peak of general RTX 4090 pulls up to 560W on 100% usage from Lab [[test]], so multip GPGPU system should take care these amount of power budget of PSU when system design and build depending on the components of the system. | |||
[[File:4090 power consumption.png|center|frameless|462x462px]] | |||
== References == | |||
<references /> |
Latest revision as of 11:55, 24 July 2023
GeForce RTX 4090 blower models comes from Manli and Gallaxy
4090 Power consumption
Although RTX 4090 default max. power cap shows 450W from the output of nvidia-smi command.
The actual power consumption including peak of general RTX 4090 pulls up to 560W on 100% usage from Lab test, so multip GPGPU system should take care these amount of power budget of PSU when system design and build depending on the components of the system.